PENSKY MARTEN FLASH POINT APPARATUS
PENSKY MARTEN FLASH POINT APPARATUS

PENSKY MARTEN FLASH POINT APPARATUS

Price 12000 INR/ Piece

MOQ : 1 Piece

PENSKY MARTEN FLASH POINT APPARATUS Specification

  • Usage
  • Use for Laboratory
  • Product Type
  • Apparatus
  • Weight
  • 5-10 Kilograms (kg)
  • Voltage
  • 220-240 Volt (v)
  • Material
  • Steel
  • Application
  • Laboratory
  • Warranty
  • 1 Year
 

PENSKY MARTEN FLASH POINT APPARATUS Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Letter of Credit (L/C), Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T)
  • Supply Ability
  • 10 Pieces Per Week
  • Delivery Time
  • 1 Week
  • Main Export Market(s)
  • Western Europe, Asia, Australia, Middle East, Central America, Eastern Europe, South America, North America, Africa
  • Main Domestic Market
  • All India
 

About PENSKY MARTEN FLASH POINT APPARATUS

This apparatus is made as per IP 34, ASTM D 93 and IS 1448 (Part I) 1270 (P.221) and IS 1209-1953 method B. The Apparatus consists of brass test cup with handle removable cup cover with spring operated rotating shutter having Oil Test Jet/Gas Test Jet Flame Device Stirrer with flexible shaft. The assembly rests in Air Bath, which is covered, with Dome shape metal top. The cup is fitted with insulated Handle and Locking arrangement near cup flange, The assemble is kept on round shape electric heater with temp. Regulator. Suitable for operation on 220 Volts 50 cycles AC

Accurate Flash Point Determination

Engineered for laboratory accuracy, the Pensky Marten Flash Point Apparatus enables precise measurement of the flash points of oils, fuels, and similar substances. Its sturdy steel construction and ergonomic design make it ideal for routine use in academic, industrial, and quality control laboratories.


Quality You Can Trust

Manufactured with meticulous attention to detail, this apparatus complies with quality standards, ensuring reliability and long-lasting performance. We stand behind our product with a one-year warranty and comprehensive support for all users.

FAQs of PENSKY MARTEN FLASH POINT APPARATUS:


Q: How does the Pensky Marten Flash Point Apparatus work in laboratory settings?

A: The apparatus is used to determine the flash point of liquid samples by gradually heating them in a closed cup and introducing an ignition source at specified intervals until a flash is observed. This process helps assess the volatility and fire hazards of substances.

Q: What materials are used in the construction of the apparatus?

A: The Pensky Marten Flash Point Apparatus is constructed from high-grade steel, making it durable and capable of withstanding the demands of daily laboratory operations.

Q: When is it advisable to use this apparatus?

A: It is recommended to use this apparatus whenever accurate determination of flash points is required, particularly during quality control analyses, research experiments, and safety evaluations of flammable liquids.

Q: Where can customers purchase the Pensky Marten Flash Point Apparatus in India?

A: Customers can purchase the apparatus directly from us, as we are a leading distributor, exporter, manufacturer, supplier, and trader across India. Contact us for sales inquiries and distribution details.

Q: What is the typical process for operating the Pensky Marten Flash Point Apparatus?

A: To operate the device, fill the sample cup with the test liquid, assemble the unit, set the required heating parameters, and apply the ignition source at intervals. Record the temperature at which a flash occurs, following standard laboratory safety protocols.

Q: Can you highlight the primary benefits of using this apparatus?

A: The primary benefits include reliable and repeatable flash point measurements, sturdy steel construction for longevity, ease of use in laboratories, and the assurance of a one-year product warranty for peace of mind.

Q: What is the voltage requirement for this apparatus?

A: The apparatus operates on a voltage range of 220-240 volts, making it suitable for standard laboratory electrical setups in India.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in OIL & PERROLEUM INSTRUMENTS Category

SOFTENING POINT APPARATUS

SOFTENING POINT APPARATUS

Price Range 9000.00 - 20000.00 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Metal

Warranty : 1 Year

Application : Laboratory

Voltage : 220240 Volt (v)

CLEAVELAND FLASH POINT & FIRE POINT APPARATUS

CLEAVELAND FLASH POINT & FIRE POINT APPARATUS

Price Range 10000.00 - 15000.00 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Steel

Warranty : 1 Year

Application : Laboratory

Voltage : 220240 Volt (v)

CARBON RESIDUE APPARATUS (CONRADSON)

CARBON RESIDUE APPARATUS (CONRADSON)

Price Range 10000.00 - 30000.00 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Stainless Steel

Warranty : 1 Year

Application : Laboratory

Voltage : 220240 Volt (v)

SMOKE POINT APPARATUS

SMOKE POINT APPARATUS

Price Range 9000.00 - 15000.00 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Metal

Warranty : 1 Year

Application : Laboratory

Voltage : 220 Volt (v)



"We are accepting only bulk quantity orders."
Back to top